Replace (Push Type) Metri-Pack Connectors Wiring Harness and Switches Disconnect the Metri-Pack 1 connector. Remove the tie bands and tape. Remove the connector lock (A), and mark wire colors for identification. RW21325 –UN–29JUN92 Identify wire color locations with connector terminal letters. Insert JDG776 or JDG777 2 Terminal Extraction Tool (B) into connector body socket (C) pushing the terminal locking tab inward. A—Connector Lock B—Extraction Tool JDG777 C—Connector Body Socket D—Terminal E—Locking Tab NOTE: Use JDG776 Extraction Tool with 56, 280 and 630 series METRI-PACK terminals. Use JDG777 Extraction Tool with 150 series METRI-PACK terminals.
Remove extraction tool and pull terminal (D) out of the socket. Replace terminal. Make sure locking tab (E) on the new terminal is in the outward position. Push terminal into connector body socket until terminal locks. 1 Metri-Pack is a trademark of Packard Electric 2 Included in JT07195A Electrical Repair Kit CED,OUO1032,1348 –19–16MAR99–1/1 Remove Connector Body from Blade Terminals 1. Use a small screw driver to depress locking tang (A) on terminal. Slide connector body off. 16 1674 16 2. Be sure to bend locking tang back to its original position (B) before installing connector body.
RW4218 –UN–23AUG88 TM1859 (14JUL04) 16-1674-16 700H Crawler Dozer CED,OUTX547,153 –19–21OCT98–1/1 071404 PN=374