R134a Refrigerant Theory of Operation Heating and Air Conditioning 18 1830 8 T117311 –19–21SEP98 A—Compressor E—High Pressure Liquid I—Expansion Valve L—Blowers B—High Pressure Gas F—High Pressure Switch J—Low Pressure Liquid M—A/C Freeze Switch C—Condenser Fans G—Low Pressure Switch K—Evaporator N—Low Pressure Gas D—Condenser H—Receiver/Dryer The compressor (A) draws low pressure gas (N) from the evaporator (K) and compresses it into high pressure gas (B). Increasing the pressure of the R134a refrigerant causes its boiling point to rise to a temperature higher than the outside air temperature. temperature drop in the refrigerant causing refrigerant to vaporize.

The expansion valve (I) is one of the dividing lines between the high side and low side of the air conditioning system. At this point in the system, the high pressure/high temperature liquid R134a is sprayed into the evaporator (K) where it changes and becomes a gas. High pressure gas (B) leaves the compressor (A) and passes through the condenser (D), the condenser fans (C) draws air through the condenser core which cools the R134a refrigerant. Cooling the refrigerant causes it to condense and it leaves the condenser (D) as a high pressure liquid (E). The high pressure liquid passes through two switches (F and G). These switches monitor R134a refrigerant pressure.

Should the pressure become too great or too small, either the high or low pressure switch will open and stop the compressor, interrupting the cycle. From the switches the high pressure liquid flows into the receiver/dryer (H) where moisture and contaminants are removed. The refrigerant flows from the receiver/dryer (H) to the expansion valve (I). The expansion valve (I) is a variable orifice used to cause a pressure and TM1859 (14JUL04) 18-1830-8 700H Crawler Dozer Continued on next page TX03399,0001853 –19–16NOV00–1/2 071404 PN=452