John Deere 700H Crawler Dozer — Compressor Oil Charge Check

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-11 700H Crawler Dozer 071404 PN=455 R134a Compressor Oil Charge Check If R134a leakage was detected and repaired. Remove 4. Flush the complete system with TY16134 air compressor. (See Remove and Install Compressor in conditioning flushing solvent. (See Flush Air this group.) Conditioner System in this group.) Drain oil from the compressor and record the amount. 5. If the compressor is serviceable, pour flushing (See R134a Compressor Oil Removal in this group.) solvent in the manifold ports and internally wash out the old oil. NOTE: Drain oil and save if this is a new compressor. 6. Install a new receiver-dryer.

(See Remove and If the oil drained from a compressor removed from Install Receiver-Dryer in this group.) operation is very black or the amount of oil is less than 6 mL (0.2 fl oz), perform the following: 7. Install required amount of TY22025 refrigerant oil in the compressor. (See R134a Component Oil Specification Charge in this group.) Compressor Oil—Volume............................ 6 mL (0.2 fl oz) minimum 8. Connect all components. 1. Remove and discard the receiver-dryer. (See Remove and Install Receiver-Dryer in this group.) 9. Evacuate the system. (See Evacuate R134a System in this group.) 2. Remove, clean, but do not disassemble the expansion valve. (See Remove and Install 10.

Charge the system. (See Charge R134a System Expansion Valve in this group. in this group.) 3. Purge the complete system. (See Purge Air Conditioner System in this group.) CED,OUTX547,173 –19–16NOV00–1/1 18 1830 11