John Deere 700H Crawler Dozer — Component Oil Charge

Heating and Air Conditioning TM1859 (14JUL04) 18-1830-13 700H Crawler Dozer 071404 PN=457 R134a Component Oil Charge 2. System not Flushed CAUTION: All new compressors are charged with a mixture of nitrogen, R134a refrigerant When the complete system was not flushed add the and TY22025 (R134a) refrigerant oil. Wear correct amount of oil for the compressor plus the safety goggles and discharge the amount of oil for each component that was compressor slowly to avoid possible injury. serviced. Compressors can be divided into three categories • New compressor from parts depot, drain and when determining the correct oil charge for the system. return oil.

(See R134a Compressor Oil Removal in this group.) Refill new compressor with 45 mL • New compressor from parts depot (1.5 fl oz) of oil. • Used compressor removed from operation • Compressor internally washed with flushing solvent Specification Oil, New Compressor Use the following procedure to determine the Installation, Complete System amount of system oil charge prior to installation of Not Flushed—Volume.......................... Drain and return 45 mL (1.5 fl compressor on a machine. oz) 1. System Flushed • Used compressor removed from operation, drain When the complete system, lines, and components oil.

(See R134a Compressor Oil Removal were flushed add the correct amount of oil as procedure in this group.) Refill used compressor described. with 45 mL (1.5 fl oz) of new oil. • New compressor from parts depot contains the Specification amount of new oil of 230 ± 20 mL (7.7 ± .7 fl oz). Oil, Used Compressor System requires an additional amount of new oil Installation, Complete System of 32.5 mL (1.1 fl oz) of new oil. Not Flushed, Oil Drained— Volume............................................................... Add 45 mL (1.5 fl oz) Specification Oil, New Compressor Installation, Complete System Flushed—Volume....................................

230 ± 20 mL (7.7 ± .7 fl oz) supplied by parts depot 3. Used Compressor Flushed (System Not Volume................................................... 32.5 mL (1.1 fl oz) additional amount required Flushed) • Used compressor removed from operation, oil drained and flushed. (See R134a Compressor Oil • Used compressor removed from operation, oil Removal in this group.) Refill 60 mL (2.0 fl oz) of drained, and flushed requires 260 mL (8.8 fl oz) new oil. of new oil. Specification Specification Oil, Used Compressor Oil, Used Compressor Installation, Complete System Installation, Complete System Not Flushed, Oil Drained, Flushed—Volume...................................................

260 mL (8.8 fl oz) Flushed—Volume.............................................. Add 60 mL (2.0 fl oz) Continued on next page CED,OUTX547,175 –19–16NOV00–1/2 18 1830 13