TCD 2015 Railway Fuel system W 07-01-03 Removing and installing fuel shut-off valve (flame glow plugs) Commercial available tools Attention! Pay attention to utmost cleanliness when working on the fuel system. Remove residue paint and particles of dirt before removing. Clean the respective affected parts care- fully. Blow damp areas dry with compres- sed air. Observe the safety regulations and natio- nal specifications for handling fuels. Close all connections immediately after opening with new, clean plugs/caps. Do not remove plugs/caps until immedia- tely before assembling. Collect leaking operating substances in suitable vessels and dispose of according to regulations. Special tools:
– Plugs/caps . . . . . . . . . . . . . . . . . 170160 6 Removing fuel shut-off valve Unlock cable plug (1) and remove. 1 © 42020-2 © 06/2006 8211-001 1/6