Deutz TCD 2015 — OBJ BUCH-190-001

TCD 2015 Fuel system W 07-06-04 Checking and setting plunger lift of injection pumps Commercial available tools: – Feeler gauges W 04-06-03 W 06-06-04 W 06-06-04 . . . . . . . . . . . .(A-bank, Railway) W 06-06-04 . . . . . . . . . . . .(B-bank, Railway) W 07-04-01 . . . . . . . . . . . .(Cylinder A1) W 07-04-01 . . . . . . . . . . . .(Cylinder A2-B3) Special tools: – Dial gauge. . . . . . . . . . . . . . . . . . 100410 – Dial gauge holder with stylus extension. . . . . . . . . . 103240 – Measuring pin . . . . . . . . . . . . . . . 110180 – Plugs/caps . . . . . . . . . . . . . . . . . 170160 – Packing compound DEUTZ DW 48 – Locking agent DEUTZ DW 72 Attention!

Pay attention to utmost cleanliness when working on the fuel system. Remove residue paint and particles of dirt before removing. Clean the respective affected parts care- fully. Blow damp areas dry with compres- sed air. Observe the safety regulations and natio- nal specifications for handling fuels. Close all connections immediately after opening with new, clean plugs/caps. Do not remove plugs/caps until immedia- tely before assembling. Collect leaking operating substances in suitable vessels and dispose of according to regulations. 6 Read out error memory of the motor con- trol timer with SERDIA. Checking plunger lift of injection pumps Remove injection pumps (cylinder A1).

W 07-04-01 Remove injection pumps (cylinder A2-B3). W 07-04-01 Do not remove injection pump housing. Attach turning gear. W 04-06-03 © 40495-0 © 06/2006 8218-001 1/14