TCD 2015 Cooling system W 09-08-01 Checking the thermostat when uninstalled Commercial available tools: – Thermometer W 09-08-02 Danger! Risk of injury! Hot water and hot thermostat. 6 Checking thermostat Remove thermostats. W 09-08-02 Measure beginning of stroke, dimension (a). Note measured value, dimension (a). © 34679-3 Heat up the thermostat in the water bath. Determine beginning of opening. In order to determine the exact beginning of opening, the temperature should be measured as close as possible to the ther- mostat. Do not touch the thermostat. The water should be continuously stirred for an even temperature distribution.
The temperature rise should not take place faster than 1°C/min. Otherwise the begin- ning of opening will be delayed accordin- gly. P09 11 P09 12 © 34680-2 © 06/2006 8236-001 1/2