Deutz TCD 2015 — OBJ BUCH-190-001

TCD 2015 Cooling system W 09-08-04 Visually inspect the components. 6 © 40893-0 Installing thermostat housing Clean sealing surfaces. 1 Mount new gasket. Mount thermostat housing (1). Do not move gasket. Plug in the cable plug (2). 2 © 40892-0 Fasten screws. Note different screw lengths. M8 x 90 mm (1) M8 x 65 mm (2) 1 2 1 2 © 40894-0 © 06/2006 8238-001 4/8