Deutz TCD 2015 — OBJ BUCH-190-001

TCD 2015 Cylinder head I 01-06-04 Press in valve guide Mount cylinder head. Select valve guide to fit housing bore. P01 11 P01 12 P01 13 6 © 39754-1 Supercool valve guide in liquid nitrogen. Use a suitable container for the liquid nitro- gen and a suitable tool for inserting and removing the components. At the beginning of the metal cooling, the liquid nitrogen boils strongly, the bubbling up process continues until the metal parts have reached the temperature of the liquid nitrogen (-196 °C). The valve guide has the correct tempera- ture if the bubbling up process of the nitro- gen has finished. © 36636-1 Push valve guide (1) onto press-in pin (2).

Note post-assembly position of the valve guide. The remote side (arrow) must face the press-in pin. 1 2 © 39755-1 © 06/2006 8159-001 5/6