. ATTACHMENTS, OPTIONS STARTING IN COLD AREAS Cable specifications and installing procedure 1. Purchase locally a 3-core Type 2 EP rubber insulated heavy-duty chloroprene sheath cable, using the specifications in the diagram on the right for reference. The nominal cross-sectional area of one core should be 14 mm 2 . Use a cable with a voltage resistance capacity of 3000 V for 1 minute. To prevent any drop in the voltage, keep the length within 30 m (98 ft). cable. The connector has 3 contacts and each is provided with a code, so connect the cable core wires as shown in the chart below.

CAUTION 6 - 5 MANUFACTURING EXTERNAL POWER SOURCE INP UT CABLE The external power source input cable must be made locally to match the local conditions, but this does not mean that any type of cable can be used. The following explains the procedure for making the cable and precautions to be followed when making it, so follow this procedure when making the cable. 2. Connect the machine input connector (sent as an individ ual part) 426-06-11630 (Connector) to the end of the Always weld the connections between the connector and the cor e wire.

Fit the welding parts with a rubber tube or wrap with insulating ta pe to insulate the welding parts and prevent short circuits caused by contact between semiconductors. Always use 426-06-11630 for the connector. If any other connec tor is used, it will be impossible to connect to the external power source input receptacle. 3. Modify the other end of the cable so that it can be conne cted to the power supply facility shown in Diagram 1. When the connection modification is finished, the extern al power source input cable is completed.