Komatsu — MACHINE MONITOR

. OPERATION EXPLANATION OF COMPONENTS MULTI MONITOR 3 - 11 DISPLAY ITEMS (WARNING ITEMS ) The main warning items displayed on the multi monitor are shown in the table below. If th e warning display is given, take actio n according to the instructions on the screen No. Item Display range Warning output Cansel switch Yes, No Error Code No.

Remarks Multi monitor warning display Screen color Main monitor output Buzzer CHECK lamp CAUTION lamp 1 Engine oil level Below low level Abnormal Red Flashes - - Yes C253 2 Engine oil pressure Below specified pressure Abnormal Red - Flashes Sounds No C143 3 Engine water temperature More than 102°C Abnormal Red - Flashes Sounds Yes C151 4 Fuel level Below specified level Lack of fuel Yellow Flashes - - Yes B@BFZK Before engine runs Below specified level Lack of fuel Yellow - Flashes - Yes b@BFZK After engine runs 5 Torque converter oil temperature More than 120°C Abnormal Red - Flashes - Yes B@CENS More than 130°C Abnormal Red - Flashes Sounds Yes b@CENS 6 Hydraulic oil temperature More than 105°C Abnormal Red - Flashes - Yes B@HANS 7 Brake oil pressure (F) Less than 14.72 MPa (150 kg/cm2, 2130 lbft) Under ac- cumulated pressure Yellow - Flashes - Yes 2G41MB Abnormal Red - Flashes Sounds No 2G42ZG 8 Brake oil pressure (R) Less than 14.72 MPa (150 kg/cm2, 2130 lbft) Under ac- cumulated pressure Yellow - Flashes - Yes 2G41MB Abnormal Red - Flashes Sounds No 2G43ZG 9 Battery electrolyte level (1) Below low level Abnormal Yellow Flashes - - Yes B@GAZK 10 Battery electrolyte level (2) Below low level Abnormal Yellow Flashes - - Yes B@GBZK 11 Battery electrolyte level (3) Below low level Abnormal Yellow Flashes - - Yes B@GCZK 12 Brake oil level Below specified level Abnormal Yellow Flashes - - Yes B@C5ZK Below specified level Abnormal Red - Flashes Sounds No b@C5ZK 13 Engine water level Below low level Abnormal Yellow Flashes - - Yes B@BCZK Before engine runs Below low level Abnormal Red - Flashes Sounds No b@BCZK After engine runs 14 Transmission filter clogging Above specified pressure Abnormal Yellow Flashes - - Yes 15B0NX 15 Air cleaner clogging (1) Above specified pressure Abnormal Yellow Flashes - - Yes AA1ANX 16 Air cleaner clogging (2) Above specified pressure Abnormal Yellow Flashes - - Yes AA1BNX 17 Air cleaner clogging (3) Above specified pressure Abnormal Yellow Flashes - - Yes AA1CNX 18 Air cleaner clogging (4) Above specified pressure Abnormal Yellow Flashes - - Yes AA1DNX 19 Defective charge amount, voltage When charge is defective Abnormal Yellow Flashes - - Yes AB00MA