The total available cooling capacity of the system is 11.1 gallons per minute (GPM). Please refer to the chart below for the available coolant flow dependent on your vehicle configuration. In-transit coolant draw and vehicle component draw MUST NOT EXCEED 11.1 GPM. Exceeding the cooling system capacity will result in engine component failures. Available Fittings for Specific Applications Note: Contact your local Mack dealer to order these fittings.

W2123680 Mack Body Builder Instructions PI / CHU, AN / CXU, GR / GU, TD, LR, TE / MRU USA141023213 Date 2.2018 Body Builder; Engine, MP7, MP8, and MP10 Page 36 (40) All Rights Reserved mDrive Cooler Artic Fox Heater In Transit Heater OK/ NOK Available Flow for Extra Components (GPM) X X X Not OK N/A X X OK None X X OK Depends on how much the transit heater demands. The transit heat- er may demand no more than 5 GPM. X OK 5 GPM X X OK Depends on how much the transit heater demands. The transit heat- er may demand no more than 6.1 GPM. X OK 6.1 GPM X OK Depends on how much the transit heater demands. The transit heat- er may demand no more than 11.1 GPM. OK 11.1 GPM