. OPERATION EXPLANATION OF COMPONENTS 3 - 47 When using automatic reverse Switchin g from normal rotatio The f an will switch from no rmal rotation to rever se rotatio n only if al l the f ollowing conditions are fulfilled. If the direction is switched achine monitor will change from flashing and will stay lighte If all the conditions are not fulfilled, the fan direction will n ot change If the direction is not switch ed, the cooling fan r everse rot ation pilot lamp on the machine monitor will change from OFF to flashing and will co Conditions Position (a) of the cooli ng fan auto reverse r otation swi tch is pressed. The engine water temp erature is less than 1 02°C.
The HST oil temperatur e is above 13°C and below 100 The boost temperature At least 30 seconds has passed since the e ngine was started. The specified time for s witching has passed. Switching from reverse rotation to norma l rotation n if both of the following conditions are fulfilled. The f an will switch from re verse rotation to nor mal rotatio n if both of the f ollowing conditions are fulfilled. If the direction is switched, the cooling fan revers e rotation pilot lamp on th e machi ne monitor will c hange as follows: Lighted up -> flashing -> O FF. are fulfilled, the fan direction will not change.
If neithe r of the conditions are fulfilled, the fan d irection wi If the direction is not switch ed, the cooling fan r everse rot ation pilot lamp on the machine monitor will change from being lighted up to flashing and will continue to Conditions A position other than po sition (a) of the coolin g fan auto reverse rotation switch is pressed durin g reverse rotation of th e fan. ime for continuous running of automatic fan reverse operation. After completion of the t ime for continuous r unning of a utomatic fan re verse o peration