. MAINTENANCE SERVICE PROCEDURE CLEAN ELEMENT IN AIR CONDITIONER FRESH AIR FILTER WARNING LOCK (PAGE 3-62)". the cover. Use the starting switch key to lock the cover. Do not forget to remove the starting switch key. REMARK 4 - 46 If compressed air is used, th ere is danger that dirt m ay fly an d caus e person al injury. Always wear protective glas ses, dust mask, and oth er protective eq uipment. If th e air conditioner has been used, the air filt er shoul d be c leaned. Stop the air conditioner b efore cleaning the el ement. Articulate the machine fu lly to the right before replacin g the air filter element 1.
I nsert the starting key into key slot (1), rele ase the lock, l oosen knob (2), and open c For details of the met hod of opening and cl osing th e cove r, see "METHOD OF OPE WITH 2. Raise knob (5), take out element (4), and clean it. g/ cm2, 99.4 3. Direct dry compresse d air (less than 0.69 M Pa (7 k g/ cm2 f 4. PSI)) to the element from inside along its folds, t hen direct it cannot be it rom outside along its folds and again from inside. Replace the filter wit h a new part if the clogging removed with compre After cleaning, return ssed air, or if it has b filter (4) to its origina een use l positio d for 1 n and year.
close If th e filter becomes clogg ed, the air flow will be reduce d, and there wil l be an a bnormal noise from t he air conditione unit.