Engine Operation 68 UENR4490-01 Illustration 62 g03711262 Schematic for the temperature sensors for the Clean Emissions Module (CEM) with a DOC/DPF/SCR The air inlet temperature sensor and the coolant temperature sensor are passive sensors. Each sensor provides a temperature input to the ECM. The ECM controls following operations: Fuel delivery Injection timing The operating range for the sensors . . . . . . . . . . . . . . . . . −40° to 125°C ((−40° to 257°F)) The operating range for the fuel temperature sensor . . . . . . . . . . . . . . . . . −40° to 120°C ((−40° to 248°F)) The sensors are also used for engine monitoring.