Perkins — Perkins 1204F-E44TA and 1204F-E44TTA Industrial Engine Systems Operation Manual

UENR4490-01 91 Air Inlet and Exhaust System The following levels of boost pressure indicate a potential problem with the wastegate actuator or wastegate regulator: Note: The wastegate actuator is installed to the high- pressure turbocharger. Too high at full load conditions 1. Disconnect the pipe for the boost sensor (1) at the wastegate actuator (2). Connect an air supply to the wastegate actuator that can be adjusted accurately. Too low at all lug conditions The boost pressure controls the maximum rpm of the turbocharger, which controls the position of the wastegate. The following factors also affect the maximum rpm of the turbocharger: 2.

Install Tooling (A) to the turbocharger so that the end of the actuator rod (3) is in contact with Tooling (A). This will measure axial movement of the actuator rod (3). The engine rating 3. Slowly apply air pressure to the wastegate so that the actuator rod (3) moves 1.0 mm (0.039 inch). Refer to Specifications, “Turbocharger” for the correct pressure for the wastegate. Ensure that the dial indicator returns to zero when the air pressure is released. Repeat the test several times. This will ensure that an accurate reading is obtained. The power demand on the engine The high idle rpm Inlet air restriction Exhaust system restriction Note: Check the operation of the wastegate regulator.

Refer to Troubleshooting, “Solenoid Valve - Test”. 4. If the operation of the wastegate is not correct, the turbocharger will need to be replaced. Check the Wastegate for Proper Operation 5. Repeat steps 2 to 3 in order to repeat the pressure test. 6. If the air pressure is correct, remove the air supply. Remove Tooling (A). Install the pipe for the boost sensor (1). Table 4 i05934751 Turbocharger - Inspect (Single Turbocharger) Hot engine components can cause injury from burns. Before performing maintenance on the en- gine, allow the engine and the components to cool. NOTICE Keep all parts clean from contaminants. Contaminants may cause rapid wear and shortened component life.

Illustration 79 g03706106 Typical example Required Tools Tool Part Number Part Description Qty A 21825617 Dial Indicator Group 1