OPERATIONAL PERFORMANCE TEST / Component Test Adjustment of Torque Control (Fan Pump Regu- lator Only) The torque control is performed by pump delivery pressure P. Therefore, the torque constant control is adjusted by changing the set-force of inner spring (2) and outer spring (1). (Before adjusting screws (4) and (6), mark the end of the adjusting screw with a white marker for the re- cord of the original position.) When resetting inner spring (2), loosen nut (5) and adjusting screw (6). When resetting outer spring (1), loosen nut (3) and adjusting screw (4). NOTE: When adjusting screw (4) is turned, inner spring (2) set-force varies.
Therefore, when adjusting screw (4) is turned, turn adjusting screw (6) 2.24 times the turns of adjusting screw (4) in the opposite direction to keep inner spring (2) set-force unchanged. T1J1-04-05-006 NOTE: Change in pressure when adjusting outer spring pump speed: 1750 min -1 Q Outer Spring Adjustment Data P 4, 6 Decrease Increase T157-05-04-023 T4-5-21 1 2 3 4 5 6 Adjusting Screw Turn 1/4 Flow Rate Change 8.9 L/min (2.4 US gal/min) Pressure Change 1.9 MPa (19.4 kgf/cm2) (276 psi) Engine Torque Change 15.1 N⋅m (1.5 kgf⋅m) (11.1 lbf⋅ft)