Hitachi Construction Machinery — Dr.ZX Monitor Indicating Values (MC)

OPERATIONAL PERFORMANCE TEST / Standard T4-2-9 Item Reference Value Measured Value Remarks First Second Third Average PUMP 1 DELIVERY PRESSURE * (MPa) Control Lever in Neutral 0.7 Boom Raise 34.3 When relieving Boom Lower - Arm Roll-In 31.9 When relieving Arm Roll-Out 31.9 When relieving Bucket Roll-Out 31.9 When relieving Bucket Roll-In 31.9 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In Combined Operation 31.9 When relieving PUMP 2 DELIVERY PRESSURE * (MPa) Control Lever in Neutral 0.7 Boom Raise 34.3 When relieving Boom Lower - Arm Roll-In 31.9 When relieving Arm Roll-Out 31.9 When relieving Bucket Roll-Out 0.7 When relieving Bucket Roll-In 0.7 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In Combined Operation 31.9 When relieving