OPERATIONAL PERFORMANCE TEST / Standard T4-2-11 Item Reference Value Measured Value Remarks First Second Third Average PUMP 1 FLOW CONTROL PRESSURE * (MPa) Control Lever in Neutral 0.04 Boom Raise 4.0 When relieving Boom Lower - Arm Roll-In 4.0 When relieving Arm Roll-Out 4.0 When relieving Bucket Roll-Out 4.0 When relieving Bucket Roll-In 4.0 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In Combined Operation 4.0 When relieving PUMP 2 FLOW CONTROL PRESSURE * (MPa) Control Lever in Neutral 0.04 Boom Raise 4.0 When relieving Boom Lower - Arm Roll-In 4.0 When relieving Arm Roll-Out 4.0 When relieving Bucket Roll-Out 0.04 When relieving Bucket Roll-In 0.04 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In Combined Operation 4.0 When relieving PUMP 1 LOAD FACTOR (%) 25 When relieving boom or arm PUMP 2 LOAD FACTOR (%) 25 When relieving boom or arm