. OPERATION DETAILED CONTROLS AND GAUGES Emergency Pump Drive Switch NOTICE Swing Brake Cancel Switch (a) FREE: When abnormal (move switch backward) (b) NORMAL: When normal (move switch forward) 3 - 67 when any problem ept in emergency. Furthermore, rem ove the cause of the problem im mediate If this switch is depresse d and moved to the EMERGENCY p osition by mistake, thereby enga ging th e machine in the work, rmal condition, an "E02" mark is s hown in th e display. g the work, check that the switch i s in the NORMAL position.
This switch (7) is used to make it possible to carry out op erations temporarilyif any problem should occur in the pump contro l system (when the display shows "E02"). (a) EMERGENCY: When abnormal (move switch backw (b) NORMAL: When orma l(move switch forward) If the display shows "E02" , move the switch up to make it possible to carry out work. NOTICE This switch makes it possibl e to perform swing operations for a short tim e even when there is a proble m in the swing p arking brake electric system. DO NO T use this switch except in emergencies. Repair the problem as soo n as possible.
This switch (8) is used to make it possible to carry out op erations temporarily if any problem should occur in the swing parki ng brake system (when the upper does not show "E03"). structure does not swing but the display If the display does not s how "E03", move the switch up to FREE position (a) to make it possible to carry out work. When the switch is mo ved to FREE position (a), the s wing lock monitor flashes.