PPC valve STRUCTURE AND FUNCTION, MAINTENANCE STANDARD 3. When in fine control mode (When control lever is returned) If lever (8) begins to return, the force of centering spring (3) and the pressure in port P1 push up spool (1). As a result, fine control hole f is connected to drain chamber D and the oil in port P1 is released. If the pressure in port P1 lowers too much, spool (1) is pushed down by metering spring (2) and fine control hole f is disconnected from drain chamber D and con- nected to pump pressure chamber PP almost simulta- neously. Then, the pump pressure is applied until the pressure in port P1 is restored to the level correspond- ing to the position of the lever.
When the control valve spool returns, the oil in drain chamber D flows in through fine control hole f of the valve which is not in operation and then flows through port P2 into chamber PA . 4. When lever is operated to stroke end If lever (8) and rod (7) push down piston (12) and retain- er (11) pushes down spool (1), fine control hole f is dis- connected from drain chamber D and connected to pump pressure chamber PP . Accordingly, the pilot oil from the main pump flows through fine control hole f and port P1 into chamber PB and pushes the control valve spool. The oil returning from chamber PA flows through port P2 and fine control f' into drain chamber D . 10-184 WA470-5H / WA480-5H