Fuel system 5. Make a mark on the pressure filter cover (B). Unscrew the cover 3 to 4 turns, use the sock- et. Draw out fuel which may drain into the water separating suction filter housing when the pressure filter is detached. B IMPORTANT! Wait a minimum of 2 minutes to allow as much of the fuel as possible to drain out of the filter housing. 329 249 6. Unscrew the pressure filter cover (B) and lift it up slowly with the filter element. B 7. Fuel from the pressure filter housing (B) will flow into the water separating suction filter housing (A). Leave the bleeding tool in the water separating suction filter housing (A) until it is completely drained of fuel.
A 329 250 OPM 300 en-GB 59 © Scania CV AB 2015, Sweden