TROUBLESHOOTING/ Monitor Unit Display of Meters Data to be displayed on each meter from are dis- played on the monitor unit according to the input signal from sensor, the signal received by using CAN and the internal data of monitor unit. Items to be displayed 1. Coolant Temperature Gauge (Input signal from the coolant temperature sensor) 2. Hour Meter (Internal data of the monitor unit) 3. Fuel Consumption Gauge (Input signal from the fuel sensor) 4. Clock (Signal received from ICF by using CAN) Work Mode Display The attachments being used are displayed accord- ing to the signals received from MC by using CAN.
Work Mode 2 1 3 4 T1V1-05-01-008 Digging Mode T1V1-05-01-108 Attachment Mode Breaker T1V1-05-01-104 Pulverizer T1V1-05-01-105 Crusher T1V1-05-01-106 Vibrating Hammer T1V1-05-01-107 Others T1V1-05-02-003 NOTE: The items on monitor unit and HITACHI pattern are same. T5-2-2 Monitor Unit HITACHI pattern Breaker1 Hydraulic Breaker1 Breaker2 Hydraulic Breaker2 Pulverizer1 Secondary Crusher1 Crusher1 Primary Crusher1