hitachi — CAN Harness Check

TROUBLESHOOTING / Troubleshooting A Discontinuity Check in CAN Harness IMPORTANT: Before continuity check, turn the key switch OFF. In case of continuity, the circuit between CAN (high side) circuit and CAN (low side) circuit is shorted. In case of discontinuity, the circuit is normal. Connector MC-C Check for continuity between terminals #C4 and #C15 of harness end of connector MC-C in MC. Connector ECM Check for continuity between terminals #18 and #37 of harness end of connector in ECM. Connector Monitor-B in Monitor Unit Check for continuity between terminals #B6 and #B7 of harness end of connector monitor-B in the monitor unit.

MC Connector MC-C (Harness end) Monitor Unit Connector Monitor-B (Harness end) #B7 #B6 C23 C31 T183-05-04-013 ECM Connector (Harness end) #18 #37 T1GR-05-04-002 Connector ICF-C Check for continuity between terminals #C5 and #C11 of harness end of connector ICF-C in ICF. T1V1-05-04-002 T5-5-72 #C4 #C15 C1 C10 ICF Connector ICF-C (Harness end) #C5 #C11 #C5 #C11