hitachi — Proportional Solenoid Valve Failure MC Fault Code 11400

TROUBLESHOOTING / Troubleshooting A PROPORTIONAL SOLENOID VALVE FAILURE MC FAULT CODE 11400 pump2 flow rate limit control solenoid valve. · Between terminal #A16 of connector MC-A in MC and terminal #2 of connector in maximum pump2 flow rate limit control solenoid valve Connector (Harness end of connector viewed from the open side) MC Connector MC-A #A16 #A22 T183-05-04-008 Maximum Pump 2 Flow Rate Limit Control Solenoid Valve T1V1-05-04-003 T5-5-85 Fault Code Trouble Cause Influenced Control 11400-2 Abnormal Current Feedback of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current:

Both of Higher than 920 mA or Less than 60 mA • Pump 2 Flow Rate Limit Control • Pump 2 Flow Rate Control Valve at Travel (ZX160-3 Class Only) 11400-3 Abnormal Feedback High Cur- rent of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current: Higher than 920 mA • Pump 2 Flow Rate Limit Control • Pump 2 Flow Rate Control Valve at Travel (ZX160-3 Class Only) 11400-4 Abnormal Feedback Low Cur- rent of Maximum Pump 2 Flow Rate Limit Control Solenoid Valve Current:

Less than 56 mA • Pump 2 Flow Rate Limit Control • Pump 2 Flow Rate Control Valve at Travel (ZX160-3 Class Only) Switch connectors of Faulty maximum pump2 YES maximum pump2 flow flow rate limit control so- rate limit control sole- lenoid valve. YES noid valve and torque control solenoid valve. Check if fault code in Faulty MC. torque control solenoid NO Check for continuity in valve is displayed. harness between MC and maximum pump2 flow rate limit control solenoid valve. · Between terminal #A22 of connector MC-A in MC and terminal #1 of Open circuit in harness. connector in maximum NO Faulty maximum pump2 flow rate limit control so- lenoid valve. Open circuit in harness. NO