hitachi — Monitor Unit Fault Code 13311

TROUBLESHOOTING / Troubleshooting A MONITOR UNIT FAULT CODE 13311 Connector (Harness end of connector viewed from the open end) Fuel Sensor 2 1 T178-05-05-001 T5-5-121 Fault Code Trouble Remedy 13311-3 Shorted Circuit in Fuel Level Sensor Check the fuel level sensor and harness. 13311-4 Open Circuit in Fuel Level Sensor Check the fuel level sensor and harness. Shorted circuit in harness YES between monitor unit and With connector of fuel sensor. level sensor discon- nected, disconnect con- nector monitor-C in YES monitor unit. Connect terminal #1 of Check for continuity be- tween terminal #C2 of harness end of connec- YES Faulty monitor unit.

tor in fuel level sensor to harness end of connec- machine. Check for con- tor in monitor unit and tinuity between terminal machine. Check if resistance of NO #C2 of harness end of fuel level sensor is connector in monitor unit Open circuit in harness specification. and machine. NO between monitor unit and sensor. Faulty fuel level sensor. NO Shorted circuit in harness between monitor unit and sensor. Faulty fuel level sensor. NO With connector of fuel level sensor discon- nected, disconnect con- nector monitor-C in monitor unit. YES Check for continuity be- tween terminal #C2 of harness end of connec- tor in monitor unit and machine. YES Faulty monitor unit.

Float Position Resistance (Ω) Upper Limit (FULL) 10+0 -4 3/4 26 1/2 38±5 1/4 53 Alarm Level 85±3 Lower Limit (EMPTY) 90+10 -0 Fuel Level Sensor Float FULL R370 257 mm 3/4 93 mm 70.5 mm 204 mm 1/2 1/4 338 mm EMPTY Monitor Unit Connector Moniter-C 6 12 · 1 7 6 1 12 7