hitachi — Relationship between Machine Trouble Symptoms and Related Parts

TROUBLESHOOTING / Troubleshooting B T5-6-14 Item Parts Function Symptoms in control system when trouble occurs. Symptoms in machine operation when trouble occurs. Solenoid Valve Unit (SG) • Temporarily increases main relief valve relief pressure in power digging and auto-power lift control. • High current: Pressure is kept increasing. • Low current: Pressure cannot increase. • High current: Pressure is kept increasing according to the valve open condition. Therefore, power increases as for all operations. • Low current: Relief pressure: 34 MPa (350 kgf/ cm2) is kept. Therefore, although the power digging switch is pushed, relief pressure does not increase. Power does not increase.

Solenoid Valve Unit (SF) • Routes return oil from boom cylinder rod side to arm cylinder bottom side during digging operation and increases arm speed. • High current: Digging regeneration control is always effective. • Low current: Digging regeneration control is always ineffective. • High current: During combined operation of boom raise and arm roll-in with suspended load and fine operation, boom does not raise easily. • Low current: During digging operation, arm operation speed is slow. (Slowdown is not remarkable.) Solenoid Valve Unit (SC) • Routes return oil from arm cylinder rod side to arm cylinder bottom side when rolling arm in and increases arm speed. • High current:

Digging power (arm) becomes weak. • Low current: Arm regeneration is always ineffective. • High current: Digging power (arm) becomes weak. • Low current: During combined operation of boom raise and arm roll-in above the ground, boom does not raise easily and maximum arm roll-in operation speed is slow.