TROUBLESHOOTING / Troubleshooting B Item Parts Symptoms in machine operation when trouble occurs. Solenoid Valve Unit (SI) High current: Travel motor is always operated at fast speed. Low current: Travel motor is always operated at slow speed. Max. Pump 1 Flow Rate Limit Solenoid Valve ZX160 - 3 class: Standard ZX180 - 3 class: Optional High current: The machine mistracks. Boom raise operation speed is slow. Arm roll-out and roll-in operation speeds are slow. Bucket roll-in and roll-put operation speeds are slow. Low current: Attachment flow rate cannot be controlled. Max. Pump 2 Flow Rate Limit Solenoid Valve High current: The machine mistracks. Boom raise operation speed is slow.
Arm roll-out and roll-in operation speeds are slow. Swing operation speed is slow. Low current: Attachment flow rate cannot be controlled. T5-6-16 Function Symptoms in control system when trouble occurs. • When pump delivery pressure is low in fast travel mode, travel motor swash angle is reduced and increases travel speed. • High current: Travel motor is always operated at fast speed. • Low current: Travel motor is always operated at slow speed. • Limits maximum pump 1 flow rate when operating attachment. • Control flow rate of pump 1 when operating travel. (ZX160-3 class only) • High current: Pump 1 flow rate becomes minimum. • Low current: Pump 1 flow rate does not decrease.
Pump 1 attachment flow rate cannot be controlled. • Limits maximum pump 2 flow rate when operating attachment. • Control flow rate of pump 2 when operating travel. (ZX160-3 class only) • High current: Pump 2 flow rate becomes minimum. • Low current: Pump 2 flow rate does not decrease.