TROUBLESHOOTING / Troubleshooting B Item Parts Symptoms in machine operation when trouble occurs. Auxiliary Flow Rate Control Solenoid Valve (Optional) High current: If valve is bound fully closed, attachment speed becomes slow during single operation. Low current: If valve is bound fully open, boom does not raise during 3-combined operation of boom raise. Auxiliary Flow Combining Solenoid Valve (Optional) Speed does not increase during single operation of attachment. Selector Valve Control Solenoid Valve (Optional) Breaker stroke becomes few. T5-6-18 Function Symptoms in control system when trouble occurs.
• Restricts flow rate to auxiliary spool during combined operation and improves operability. • If auxiliary flow rate control solenoid valve is not activated, pressure at output port becomes 0 MPa (0 kgf/cm2). • Activates during auxiliary operation and shifts spool in auxiliary flow combining valve. • If auxiliary flow combining solenoid valve is not activated, pressure at output port becomes 0 MPa (0 kgf/cm2) when operating attachment. • Activates when attachment “selector valve returning to hydraulic oil tank” is selected and shifts selector valve spool.
• If selector valve control solenoid valve is not activated, pressure at output port becomes 0 MPa (0 kgf/cm2) when attachment “selector valve returning to hydraulic oil tank” is selected.