TROUBLESHOOTING / Troubleshooting B T5-6-26 Item Parts Function Symptoms in control system when trouble occurs. Symptoms in machine operation when trouble occurs. Auxiliary Flow Rate Control Valve • Be shifted by pilot pressure from auxiliary flow rate control solenoid valve. • If spool is bound or spring is broken, orifice does not change. • If bound at fully closed position, attachment speed becomes slow. • If bound at fully open position, boom does not raise during 3-combined operation of swing, arm roll-in and boom raise. Boom Regenerative Valve • Routes return oil from boom cylinder bottom side to rod side and prevents boom cylinder hesitation.
• If check valve is kept closed, boom is not smoothly lowered. • If check valve is kept open, machine cannot be raised off ground with front attachment. • If check valve is kept closed, boom is not smoothly lowered. • If check valve is kept open, machine cannot be raised off ground with front attachment. Arm Regenerative Valve • Be shifted by pilot pressure from solenoid valve unit (SC). • Routes return oil from arm cylinder rod side to bottom side and increases arm speed. • Arm regenerative function is not operated. • Arm speed is extremely slow during arm level crowd operation while arm regenerative valve is kept closed.
• The lever operated first is given priority during combined operation of arm roll-in and swing while arm regenerative valve is kept open. Bucket Regenerative Valve • Routes return oil from bucket cylinder rod side to bottom side and prevents bucket cylinder hesitation. • If check valve is kept closed, bucket is not smoothly rolled in. • If check valve is kept open, bucket power is weak. • If check valve is kept closed, bucket is not smoothly rolled in. • If check valve is kept open, bucket power is weak.