TROUBLESHOOTING / Troubleshooting B T5-6-40 Item Parts Function Symptoms in control system when trouble occurs. Symptoms in machine operation when trouble occurs. Boom Lower Meter-In Cut Valve • Be shifted by return oil from boom cylinder bottom side. • Shifts boom flow rate control valve by boom lower pilot pressure. • If valve is kept closed, as boom flow rate control valve is not shifted, boom lower speed becomes fast during combined operation. • If valve is kept open, as boom flow rate control valve is shifted, pressure oil from pump 1 does not flow to boom 1 spool. Therefore, machine cannot be raised off ground with front attachment.
• If valve is kept closed, as boom flow rate control valve is not shifted, boom lower speed becomes fast during combined operation. • If valve is kept open, as boom flow rate control valve is shifted, pressure oil from pump 1 does not flow to boom 1 spool. Therefore, machine cannot be raised off ground with front attachment. Auxiliary Flow Combining Valve (Optional) • Be shifted by pilot pressure from auxiliary flow combining solenoid valve when attachment mode (secondary crusher, primary crusher) of travel speed “ON” is selected. • Supplies pressure oil from pump 1 to auxiliary spool. • If switch valve is kept closed, attachment speed does not become fast during single auxiliary operation.
• If switch valve is kept open, attachment speed does not become slow when attachment mode (HSB breaker, NPK breaker) of travel speed “OFF” is selected. • If switch valve is kept closed, attachment speed does not become fast during single auxiliary operation. • If switch valve is kept open, attachment speed does not become slow when attachment mode (HSB breaker, NPK breaker) of travel speed “OFF” is selected. Selector Valve (Optional) • Be shifted by pilot pressure from selector valve control solenoid valve. • If spool is bound or spring is broken, pressure oil from breaker does not return to hydraulic oil tank. • Breaker stroke becomes few.
Secondary Pilot Relief Pressure Control Valve (Optional) • Be shifted by pilot pressure from secondary pilot relief pressure control solenoid valve. • If spool is bound or spring is broken, relief circuit in breaker is blocked. • Relief set-pressure in auxiliary circuit does not decrease.