hitachi — Engine System Troubleshooting

TROUBLESHOOTING / Troubleshooting B E-7 Faulty Travel HP mode Even if the travel mode switch is turned to FAST during single travel operation, travel HP mode is not operated. Related MC Fault Code: 11004-2, 11200-3, 11200-4, 11202-3, 11202-4, 11304-3, 11304-4 The sensors detect the conditions necessary to operate travel HP mode. Therefore, if any of these sensors fails, travel HP mode becomes ineffec- tive. Pressure sensor (travel) and pump 1 and 2 deliv- ery pressure sensors are also engaged in the HP mode control. However, if these sensors fails, other operating functions will be also affected.

Refer to the pages for Travel HP Mode Control in the SYSTEM / Control System group in the T/M (Operational Principle). Check the wiring connections first. NO Faulty travel mode switch, or open circuit in harness between travel mode switch and MC. Monitor travel mode switch. When travel mode switch is shifted, check if display is changed. NO Faulty MC. · Monitor item: Travel fast speed YES NO Faulty corresponding sensor, or open circuit in harness between MC and sensor. · Fault code: 11200-3 11200-4: Pump 1 delivery pressure sensor 11202-3, 11202-4: Pump 2 delivery pressure sensor 11304-3, 11304-4: Pilot pressure sensor (travel) Refer to fault code 11004 in Troubleshooting A.

YES T5-6-68 Check if fault code is displayed. Check if fault code 11004-2 is displayed at YES the same time.