TROUBLESHOOTING / Troubleshooting B A-2 All actuator are not operated. Related MC Fault Code: None The pilot shut-off circuit may be faulty. Check the wiring connections first. When the key switch is turned to the START posi- tion with the pilot shut-off lever in the ON position, the starter does not rotate. When the key switch is turned to the START posi- tion with the emergency switch and the pilot shut-off lever in the ON position, the starter ro- tates. Refer to the pages for the Electrical System group / SYSTEM in the T/M (Operational Principle). Connector (Harness end of connector viewed from the open side) YES Faulty pilot shut-off relay.
Switch pilot shut-off relay with other gen- eral relay. Check if actuator can be operated. YES Faulty security relay. · Pilot shut-off lever: ON Switch security relay with other general relay. Check if actuator can be operated. Connect terminal #2 of harness end of con- nector in pilot shut-off solenoid valve to ma- chine. Disconnect connector in pilot shut-off relay. Check for continuity between terminal #2 of harness end of con- nector and machine. NO YES · Pilot shut-off lever: ON Disconnect connec- tor in pilot shut-off solenoid valve. Check if voltage be- tween terminal #1 of harness end of con- nector and machine is 24 V.
NO Open circuit in harness between pilot shut-off solenoid valve and bat- tery relay. · Key switch: ON NO · Check if fuse #4 is blown. · Check if fusible link 65A is blown. Pilot Shut-Off Solenoid Valve T1V1-05-04-103 #1 #2 T183-05-04-003 T5-6-88 Pilot shut-Off Relay Security Relay