TROUBLESHOOTING / Troubleshooting B F-3 Some cylinders are not operated or speeds are slow. Related MC Fault Code: None When other actuators (travel and swing) operate normally, the pilot pump (primary pilot pressure) is considered to be normal. In case single bucket operation speed is slow, refer to F-6. In case single arm roll-in operation speed is slow, refer to F-7. In case single boom lower operation speed is slow, · Possible to display by service menu and monitoring in monitor unit. boom is not raised. In case cylinders other than boom are abnormal, skip this step and go NO. T5-6-102 Bound control valve YES spool, or faulty cylinder (faulty seal kit).
Check if overload re- YES lief pressure is normal. Monitor pump control Faulty overload relief pressure. NO valve. Check if pump con- YES trol pressure changes smoothly while moving control lever slowly. Faulty shuttle valve in · Monitor item: Pump 1 pump con- NO signal control valve. trol pressure, pump Measure or monitor 2 pump control secondary pilot pressure pressure. · Possible to display Check if secondary by service menu pilot pressure is and monitoring in normal. monitor unit. Secondary pilot Bound shockless valve pressure: YES spool in signal control Refer to Operational valve. Performance Test Check if secondary section. pilot pressure at inlet Monitor item:
Boom raise pilot pressure, NO port to signal control valve. arm roll-in pilot pres- Faulty pilot valve. sure. · Check only when NO Bound control valve spool, or faulty cylinder (faulty seal kit). Faulty pilot valve. NO