hitachi — Front Attachment System Troubleshooting

TROUBLESHOOTING / Troubleshooting B F-4 Arm speed is slow during combined opera- tion. During combined operation of boom raise and arm roll-in, boom raise speed is slow. Arm speed is slow during arm level crowding. Related MC Fault Codes: 11200-3, 11200-4, 11202-3, 11202-4, 11303-3, 11303-4, 11301-3, 11301-4, 11302-3, 11302-4, 11403-2, 11403-3, 11403-4 Refer to the pages for the SYSTEM / Control System group / Arm Regenerative Control in the T/M (Operational Principle). Check if fault code is displayed. Check if arm 1 flow rate control valve at 5-spool side in control valve is scored or bound. YES · Fault code 11200-3, 11200-4: Pump 1 delivery pressure sensor 11202-3, 11202-4:

Pump 2 delivery pressure sensor 11303-3, 11303-4: Pressure sensor (arm roll-in) 11301-3, 11301-4: Pressure sensor (swing) 11302-3, 11302-4: Pressure sensor (boom raise) 11403-2, 11403-3, 11403-4: Solenoid valve unit (SC) Install a pressure gauge to hose SE connecting from signal control valve to arm flow rate control valve in control valve. When relieving during combined operation of swing and arm roll-in, check if pressure is 3.9 MPa (40 kgfcm 2 ). Check if arm regenerative valve at 4-spool side in control valve is scored or bound. NO NO Signal Control Valve (Control Valve Side) Faulty control spool in arm flow rate control valve (signal control valve).

NO Control Valve Hose SE T1V1-05-04-004 Arm 1 Flow Rate Control Valve T178-03-06-015 T5-6-104 YES Faulty corresponding sen- sor, or faulty MC. Open circuit in harness between MC and sensor. Faulty solenoid valve unit (SC), or open circuit in harness between solenoid valve unit (SC) and MC. YES YES Faulty arm 1 flow rate con- trol valve.