hitachi — Swing System Troubleshooting

TROUBLESHOOTING / Troubleshooting B S-2 Swing is slow (weak in power) during com- bined operation of swing and arm roll-in. Swing does not start smoothly. Swing power is weak. Related MC Fault Codes: 11202-3, 11202-4, 11301-3, 11301-4, 11303-3, 11303-4 Refer to the pages for the SYSTEM / Hydraulic System group / Valve Control Circuit in the T/M (Operational Principle). Check the wiring connections first. Check if fault code is displayed. · Fault code 11202-3, 11202-4: Pump 2 delivery pressure sensor 11301-3, 11301-4: Pressure sensor (swing) 11303-3, 11303-4: Pressure sensor (arm roll-in) YES Faulty arm 1 flow rate control valve in control valve.

Bound control spool in arm flow rate control valve in signal control valve. NO NOTE: In case other fault codes are dis- played, perform troubleshooting corresponding to the displayed fault code. Signal Control Valve (Control Valve Side) Hose SE T178-03-06-015 Arm 1 Flow Rate Control Valve T1V1-05-04-004 T5-6-122 YES Faulty corresponding sensor, or faulty MC. Open circuit in harness between MC and sensor. YES Install a pressure gauge to hose SE connecting from signal control valve to arm flow rate control valve in control valve. NO When relieving during combined operation of swing and arm roll-in, check if pressure is 3.9 MPa (40 kgfcm2).