hitachi — Other System Troubleshooting

TROUBLESHOOTING / Troubleshooting B STEP 3 Past Trouble Diagnosing The LCD indicates the fault codes for past abnor- malities of the mix door, mode encoder, and/or sen- sors. The past stored fault codes are deleted. In case any abnormalities occurred in the past, the LCD indicates the fault codes. If more than one fault code is detected, the following fault code is dis- played after flashing (0.5 seconds) twice. Fan Switch Air Conditioner Switch LCD T178-05-08-001 OFF Switch When the air conditioner switch is kept pushing for more than 3 seconds, the failure records are deleted. After this operation, the air conditioner switch indi- cator flashes 5 times.

Then, the self-diagnosing system is deactivated. (Normal functions are re- sumed.) Select the next step in order to be performed by operating the switches as follows: Push the upper side of fan switch: To proceed to “STEP 4.” Push the lower side of fan switch: To return to “STEP 2.” Keep pushing the OFF switch for more than 3 seconds: Deactivate the self-diagnostic system. (Normal function is resumed.) T5-6-137 Fault Code Open circuit Shorted Circuit Mix Door 21 −21 Mode Encoder 22 In-Cab Ambient Temperature Sensor 23 −23 Outdoor Ambient Temperature Sensor 24 −24 Coolant Tem- perature Sensor 25 −25 Solar Radiation Sensor −26