hitachi — Other System Troubleshooting

TROUBLESHOOTING / Troubleshooting B Normal leakage of refrigerant from hoses. Refill refrigerant. Improper adjustment (excessive restriction) of expansion valve. Readjust or replace expansion valve. Clogged expansion valve. Remove clog, or replace receiver and/or expansion valve. Clogged low-pressure circuit and/or evaporator. Remove clog, or replace parts. Frozen expansion valve or water in circuit. After evacuation, refill refrigerant and/or replace re- ceiver dryer. Gas leaks from case. Seal gaps by using vinyl tape or packing compound. Poor contact of expansion valve temperature sensing cylinder. Make good contact. Replace temperature sensing stay.

Improper adjustment (excessive open) of expansion valve. Readjust or replace. Insufficient compressor discharge (faulty gasket and/or valve). Replace. Improper water stop valve wire adjustment and/or faulty stop valve. Check and readjust or replace. Poor airtight fitting of outside air damper (outside air induction type). Repair. Clogged high-pressure circuit before receiver dryer. Remove clog, or replace parts. Clean Condenser. Excessive refrigerant. Remove excessive refrigerant to proper level. Air is mixed in system. After evacuation, refill refrigerant and/or replace re- ceiver dryer. Incorrect thermistor location. Correct thermistor location. Gas leaks from case.

Seal gaps by using vinyl tape or packing compound. Faulty thermistor (stays ON). Disconnected thermistor cord. Even if function and performance are normal, when air-conditioner is kept operated for a long time with thermistor in max. cooling position and air flow in M or L mode, frost may form. Instruct user on correct air-conditioner operation. (Reset thermistor to either minimum or middle cooling position or increase air flow.) T5-6-145 Gas leaks from pipe joints and/or parts. Re-tighten or replace parts.