hitachi — Attachment Adjiustment Data List

OPERATIONAL PERFORMANCE TEST / Standard ZAXIS160LC-3 DR. ZX MONITOR INDI- CATING VALUES Unless specified, test under the following conditions. Engine Speed: Fast Idle Work Mode: Digging Mode Power Mode Switch: P mode Auto-Idle: OFF NOTE: Items marked ( ) are measurable by using service menu/monitoring in the monitor unit. Items marked ( ) are measurable by using service menu/monitoring in the monitor unit. However, it may be difficult to read the measured value while operating the ma- chine.

T4-2-22 Item Reference Value Measured Value Remarks First Second Third Average PUMP 1 PRESSURE (MPa) ∗ Control Lever in Neutral 0.4 ∗ Boom Raise 36.3 When relieving ∗ Boom Lower - ∗ Arm Roll-in 34.4 When relieving ∗ Arm Roll-Out 34.2 When relieving ∗ Bucket Roll-Out 35.4 When relieving Bucket Roll-In* 35.4 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In ∗ Combined Operation 34.4 When relieving PUMP 2 PRESSURE (MPa) ∗ Control Lever in Neutral 0.4 ∗ Boom Raise 36.3 When relieving ∗ Boom Lower - ∗ Arm Roll-in 34.4 When relieving ∗ Arm Roll-Out 34.4 When relieving ∗ Bucket Roll-Out 0.4 When relieving ∗ Bucket Roll-In 0.4 When relieving Boom Raise + Arm Roll-In + Bucket Roll-In ∗ Combined Operation 34.4 When relieving