40 V-MAC Co-Pilot Operator's Manual Exit conditions for DEF Quality "8 Km/h (5 mph) road speed limit" Inducement: Next 1 Engine Starts: Return to 25% torque reduction until there is a proper DEF quality evaluation. If poor DEF quality is detected during the next monitoring cycle then 8 Km/h (5 mph) is resumed after the vehicle is stationary for 20 minutes. After one engine start has been exhausted then a Tech Tool is required to exit the 8 Km/h (5 mph) road speed limit. With Tech Tool DTC Clearing: Invoke 25% torque reduction until there is a proper DEF quality evaluation.

If poor DEF Quality is detected during the next monitoring cycle then 8 Km/h (5 mph) is resumed after the vehicle is stationary for 20 minutes. Triggers Aftertreatment DEF Quality Indicator Driver Information Display Screen Refueling Event with Parking Brake ON W3 031 623 SCR Performance Low Service SCR System Veh Speed Limited to 5 Mph Vehicle Stationary for 20 minutes or Engine re-start (Key OFF, Key ON) W3 031 623 SCR Performance Low Service SCR System Veh Speed Limited to 5 Mph Temporary Exit from 8 Km/h (5 mph) Inducement W3 031 623 SCR Performance Evaluation Continue Driving.

5 Mph Limit Temporarily Removed Ignition Key Cycle W3 031 623 SCR Performance Low Service SCR System Veh Speed Limited to 5 Mph First start after the key cycle (one time only) W3 031 623 SCR Performance Evaluation Continue Driving. 5 Mph Limit Temporarily Removed