54 When engine is stationary Position of starter switch 8 : ON To improve the performance of the alternator 5 in starting power generation at a low speed immediately after the engine has been started, current is set flowing to terminal R . 1 2 8 5 (R E) Ground 6 (R L) 5 (L E) Ground 16740 In the circuit with A charge lamp 7 , current flows as shown below. 1 2 8 5 (R E) Ground 7 5 (L E) Ground After engine has been started Position of starter switch 8 : ON The alternator 5 starts generating power. The output voltage at terminal B of the alternator 5 becomes higher than the voltage of the battery 1 . The alternator 5 starts charging the battery 1 .
5 (B) 4 3 8 2 1 16741 In the case of the circuit with the charge lamp 7 , the charge lamp goes out, as there is no potential difference between the voltage at terminal L of the alternator 5 and the battery voltage. 54-7