Caterpillar — Caterpillar 99709-68120 — user manual

PREHEATER CIRCUIT 1 Starter switch 2 Glow relay 3 Glow plug indicator 4 Glow plug 5 Battery relay 6 Battery 18462 Service standards 54-44 Location Maintenance item Standard value Limit Remedy 4 Resistance of glow plug at normal temperature 3.8 V – Replace N Service procedure 2 Inspection of glow relay Inspection of main body • Perform continuity checks according to the following table. ➄ ➀ ➁ ➂ ➃ (Body ground) When no current is supplied When current is + − supplied There is continuity between terminals. + − Terminals to which 24V DC is applied A: Fuse • If there is anything wrong, replace the glow relay 2. 17543 ➀ ➁ ➂ ➃ ➄ (Body ground) When no current is supplied When current is supplied + −