Additional Equipment Hydraulic System Adjusting the SCV values The following values may be adjusted for the E-SCVs and E-ICVs: Maximum flow Automatic shut-off time LX1037199 —UN—06NOV06 Press button (A) for selective control valves and set the desired values at the following screens using the selector wheel. The values for maximum flow can be set in increments of 0.1. The minimum is 0.2, and the maximum 10. The values for the shut-off time can be set in variable increments between 0 and infinity. Infinity means no automatic shut-off. NOTE:
If cell (B) is activated, the set values for maximum flow and automatic shut-off time at each of the SCVs are identical in both directions (extend/retract). If cell (C) is activated, the values for the two directions of movement can be set separately (see illustrations). LX1038331 —UN—31MAY06 A—Button for Selective Control Valves B—Joint Adjustment C—Separate Adjustment LX1041107 —UN—20NOV06 Continued on next page OU12401,0001663 -19-28OCT11-3/5 70-6 030612 PN=177