Additional Equipment Hydraulic System Automatic shut-off Provided the transport lock is not active and a shut-off time greater than zero is set for the SCV, the following applies: If the SCV control lever (see arrow) is in the maximum extend or retract position and then moved past the point of resistance (a definite click can be perceived), the relevant SCV will be brought to its maximum flow position and held there until the set shut-off time elapses. Then the control valve is moved to its neutral position. LX1037207 —UN—13OCT05 This procedure is aborted if:
the SCV control lever is not returned to its neutral position within one second the SCV control lever is moved out of its neutral position before the shut-off period has elapsed the SCV control lever is moved in the opposite direction To re-activate the automatic shut-off, cycle the SCV control lever back from beyond the point of resistance and then past the point of resistance again. In all above-mentioned cases, the SCV will react according to the movements of the SCV control lever. OU12401,0001663 -19-28OCT11-5/5 70-8 030612 PN=179