Lubrication and Periodic Service Access to Battery The battery is located in front of the radiator. To gain access, open the hood. LX1037218 —UN—21OCT05 OULXE59,0010891 -19-24APR06-1/1 Access to Fuses Most of the fuses are located behind the operator's seat. Other fuses are located in the engine compartment. LX1044929 —UN—11DEC07 OU12401,0001915 -19-10DEC07-1/1 Important Instructions Regarding Alternator NOTE: The alternator is equipped with over- voltage protection. If engine is to be run for a short time without battery (using a slave battery for starting), do not run engine at a speed above 1000 rpm. Furthermore, use additional current (lights) while engine is running.
LX1036509 —UN—19OCT05 With the battery removed and when starting by means of a slave battery, insulate the battery end of the disconnected starter cable. This will avoid damage to the alternator and regulator. Slave battery cables must be connected only to the poles provided for this purpose. Connect ground terminal of welding apparatus directly to the part being welded. With the engine running, do not short-circuit or ground the alternator and regulator even momentarily. Before carrying out repairs on electrical system, disconnect battery ground strap. This will avoid the danger of a short circuit. Connect battery and charger with the correct polarity.
If they are improperly connected and the rectifier diodes will be destroyed immediately. Before carrying out any electro-welding jobs on the tractor, disconnect the two cables at the alternator and at the battery . OULXE59,0010825 -19-13MAY06-1/1 85-5 030612 PN=214