Operating the Engine Fuel Preheater Fuel preheater (A) switches on and off automatically (ambient temperature). LX1036260 —UN—16AUG05 OU12401,0001404 -19-13MAY06-1/1 Engines with Turbocharger Most damage to the turbocharger is caused by not following the correct procedure when starting and shutting off the engine. After starting and before shutting off, idle the engine without load for at least 30 seconds. IMPORTANT: If the engine “stalls” when in operation, restart it IMMEDIATELY. This will prevent the turbocharger from overheating. OULXE59,0010944 -19-14NOV07-1/1 Intelligent Power Management (Power Boost) Optional Equipment NOTE:
Power boost is activated automatically when starting the engine. To de-activate or re-activate power boost, press engine button (A) and make a choice on the screen. LX1037624 —UN—06NOV06 If power boost is activated at the CommandCenter, then the following applies: a) Transport work Engine power is increased automatically when ground speed exceeds 15 km/h (9.3 mph). This power boost persists until the ground speed drops below 10 km/h (6.2 mph). b) PTO operation When using PTO-driven implements, engine power is increased gradually when ground speed exceeds 1 km/h (0.6 mph), if the tractor electronic system detects a correspondingly high PTO power requirement.
Full power becomes available from a speed of 2.5 km/h (1.5 mph). LX1041086 —UN—20NOV06 A—Engine button Continued on next page OU12401,00019B0 -19-23APR08-1/2 40-4 030612 PN=80