Fendt Favorit 900, 916, 920, 924, 926 — Fendt Favorit 900 Series Workshop Manual PDF (EN)

Faults Fault code Id code Brief description Description 1.1.E0 B035 Position sensor manual accelerator wrong 1.1.9E A003 Memorization keys Engine speed 1.1.7F A004 Control console 1.1.9F A002, A004 EST Comfort Control Module, Side Console 1.1.A1 A002, A021 EST control module, EDC control module 1.1.A0 A021 EDC control module 1.1.B0 CAN-bus restricted Battery 1, Battery 2, Generator, EDC control module 1.2.13 G001, G003, G001, A021 12/1999 0000 000001 B b 3/47 Capitel Docu-No. Index Date Version Page Vario Tractors - Failure Codes 12/1999 Date b Version 3/47 Page Vario Tractors - Failure Codes 0000 Capitel B Index 000001 Docu-No.

Fault code Id code Brief description Description Consequences Link FENDIAS / Note 1.1.7F A004 Control console Electrical fault in hand throttle memory keys (EDC/EMR). No communication with control console. Last speed setting is retained. Engine speed can be changed using hand throttle or accelerator. 1.1.9E A003 Memorization keys Engine speed Signal out of range.

Restricted Operating Possibilities, Chapter 2000 Reg.B (EDC-Failure) Electric diagram "EDC Control " 1.1.9F A002, A004 EST Comfort Control Module, Side Console CAN communication failure EST Control Module (A002) - Side Console (A004) Restricted Operating Possibilities, Chapter 2000 Reg.B (EDC-Failure) Electric diagram "EDC Control ", "Transmission BUS"," Comfort-BUS" 1.1.A0 A021 EDC control module EDC control module (A021) cannot be identified, EOL Programming error According to failure importance, Engine torque will be reduced to Fav.916 torque .

Chapter 2000 Reg.B (EDC-Failure) Electric diagram "EDC Control " 1.1.A1 A002, A021 EST control module, EDC control module CAN Communication failure EST control module (A002) - EDC control module (A021) Chapter 2000 Reg.B (EDC-Failure) Electric diagram Transmission -BUS (G-BUS) 1.1.B0 CAN-bus communication restricted EOL reprogramming necessary.

1.1.E0 B035 Position sensor manual accelerator Checksum EEPROM is wrong Restricted Operating Possibilities, Chapter 2000 Reg.B (EDC-Failure) Electric diagram "EDC Control " 1.2.13 G001, G003, G001, A021 Battery 1, Battery 2, Generator, EDC control module Voltage supply failure EDC control module No engine power Chapter 2000 Reg.B (EDC-Failure) Electric diagram "Voltage supply +Ub" Faults