ENGINE OPERATION 12/05 Starting with Glow plug (If Equipped) After the Engine has Started After the engine has started, check the following items at a low engine speed: 1. Open the seacock (if equipped). 2. Open the fuel tank cock. 1. Check that the gauges, indicators and alarm are normal. 3. Put remote control handle in NEUTRAL. Normal coolant operating temperature is approximately 76° to 90°C (169° to 194°F). 4. Turn the battery switch on (if equipped). 5. Push the power switch on. Ensure that the instrument panel indicators light and the alarm sounds. This shows that indicators and alarm are working correctly. Normal oil pressure at 3000 min -1 is 0.28 to 0.54 MPa (41 to 78 psi). 2.
Check for water, fuel or oil leakage from the engine. Note: The coolant high temperature alarm indicator does not come on during start-up. 3. Check that the smoke color, engine vibration and sound are normal. 4. When there are no problems, keep the engine at low speed with the boat still stopped to distribute engine oil to all parts of the engine. 6. Push and hold the glow switch for 10 seconds. 7. Push the start switch. Release the start switch when the engine has started. The alarm should stop and the indicators should go out. 5. Check that sufficient cooling water is discharged from the seawater outlet.
Operation with inadequate seawater discharge will damage the impeller of the seawater pump. If seawater discharge is too low, stop the engine immediately. Identify the cause and repair. NOTICE Never hold the start switch for longer than 15 seconds or the starter motor will overheat. NOTICE The engine will seize if it is operated when seawater discharge is too small or if load is applied without any warming up operation. For troubleshooting assistance, see Troubleshooting After Starting on page 75 or Troubleshooting Chart on page 77 . If necessary, consult authorized Yanmar dealer or distributor. YM Series Operation Manual 43