LONG-TERM STORAGE If the engine will not be used for an extended period of time, special measures should be taken to protect the cooling system, fuel system and combustion chamber from corrosion and the exterior from rusting. PREPARE ENGINE FOR LONG-TERM STORAGE Note: If the engine is close to a periodic maintenance interval, perform those maintenance procedures before putting the engine into long-term storage. The engine can normally stand idle for up to 6 months. If it remains unused for longer than this, please contact your authorized Yanmar Marine dealer or distributor. 1. Wipe off any dust or oil from the outside of engine.
Before performing any storage procedures within this section, review the Safety section on page 5 . 2. Drain water from fuel filters. 3. Drain fuel tank completely or fill the tank to prevent condensation. In cold temperatures or before long-term storage, be sure to drain the seawater from the cooling system. 4. Grease the exposed areas and joints of the remote control cables and the bearings of the remote control handle. NOTICE 5. Seal the intake silencer, exhaust pipe, etc. to prevent moisture or contamination from entering engine. Do not drain the coolant system. A full coolant system will prevent corrosion and frost damage. 6. Completely drain bilge in hull bottom. 7.
Waterproof the engine room to prevent rain or seawater from entering. If seawater is left inside of the engine, it may freeze and damage parts of the cooling system when the ambient temperature is below 0°C (32°F). 8. Charge the battery once a month to compensate for battery’s self-discharge. 9. Make sure the power switch is off. YM Series Operation Manual 79