7 Load handling – 7.5 Positioning 19 7.5 Positioning page Spreading, function description Spreading means that the width between the twistlocks is changed. Spreading has two 20-foot and 40-foot stops, as an option there are stops at other distances, e.g., 30-foot stop. 001114 Control valve attachment pressurizes valve block spreader motor that directs pressure to the spreader motor. The spreader motor pulls the spreader chains that pull the spreader booms in and out. Spreading is controlled with Control lever (S815). Inductive position sensors indicate the spreader units' position. Damping Damping means that the speed of functions are reduced automati- cally close to end-positions.
Three seconds after damping is activat- ed, the function is interrupted. This results in less loading of mechanical parts at stops in end-positions. Position sensors sense when damping should be activated. When damping is activated, the control unit in question reduces the con- trol current to the solenoid valve for that function. UDRF01.04GB Maintenance manual DRF 400–450 Condition Reference value Control switch Not activated Twistlocks Unlocked or by-pass activated Overloading system Passive